Gas Pressure Regulators
R Series – Gas Pressure Regulator, Threaded Connection PS: 16 bar
Direct-acting, spring-loaded regulation with threaded connections, rated PS 16 bar.
Product view
Manually Reset Solenoid Valves
The SV-MR latches closed after a trip and can only be reopened with the on-site reset lever, which is the behaviour codes usually demand for gas-detection and emergency-shutdown service. The lever cannot be held open against a live trip signal, so it cannot be defeated by a wedge or a cable tie.
Confirmed against your duty at order stage — send us the operating conditions and we will verify the selection.
| Parameter | Value |
|---|---|
| Design pressure | Up to 6 bar |
| Sizes | DN 15 – DN 150 |
| Closing time | < 1 s |
| Coil voltage | 230 V AC / 110 V AC / 24 V DC |
| Connections | Threaded BSP / NPT, PN16 flanged |
| Body material | Aluminium alloy or ductile iron |
Datasheets, installation manuals, drawings and conformity declarations.
Documentation for Manually Reset Solenoid Valves is issued on request against the confirmed specification. Request the document pack.

Gas Pressure Regulators
Direct-acting, spring-loaded regulation with threaded connections, rated PS 16 bar.

Gas Pressure Regulators
Direct-acting, spring-loaded regulation with flanged connections, rated PS 25 bar.

Gas Pressure Regulators
Tight accuracy at high capacity, using the gas stream itself as the control amplifier.
The more detail you give on the duty, the more precise the proposal comes back.
What engineers most often ask when specifying this equipment.
An automatic-reset valve reopens as soon as its coil is re-energised. A manual-reset valve stays closed until someone physically operates the reset lever, which is normally required for gas-detection and emergency-shutdown duties so that a plant cannot re-gas unattended.