Gas Flow Solutions

Gas Filters Pmax: 6 Bar

Product view

Gas Filters Pmax: 6 Bar

Low-pressure in-line protection for burner trains and service lines.

The GF-6 is the compact end of the range: a threaded aluminium housing with a pleated cartridge, sized for the 6 bar duty that covers almost every burner gas train and commercial service line. Its face-to-face dimension is close to a spool piece, so it drops into existing pipework without re-piping, and the element lifts out through a top closure.

Features

  • •Maximum working pressure 6 bar
  • •Retrofit-friendly face-to-face dimension
  • •Top-entry element access
  • •Lightweight aluminium body for tight plant rooms
  • •Gauge ports upstream and downstream as standard

Key features

  • Maximum working pressure 6 bar
  • Retrofit-friendly face-to-face dimension
  • Top-entry element access
  • Lightweight aluminium body for tight plant rooms
  • Gauge ports upstream and downstream as standard

Applications

  • Burner gas train pre-filtration
  • Commercial service-line protection
  • Boiler-house and plant-room installations

Technical specifications

Confirmed against your duty at order stage — send us the operating conditions and we will verify the selection.

Gas Filters Pmax: 6 Bar specifications
ParameterValue
Design pressurePmax 6 bar
Filtration grade5 – 50 μm
SizesDN 15 – DN 80
ConnectionsThreaded BSP / NPT, PN16 flanged
Body materialAluminium alloy
Temperature range−20 °C to +60 °C

Technical documents

Datasheets, installation manuals, drawings and conformity declarations.

  • GF-6 Gas Filter Pmax 6 Bar — Technical DatasheetDatasheet · PDF · on request
  • GF-6 Gas Filter Pmax 6 Bar — Installation & Maintenance ManualManual · PDF · on request
  • GF-6 Gas Filter Pmax 6 Bar — Dimensional DrawingDrawing · DWG / PDF · on request
  • GF-6 Gas Filter Pmax 6 Bar — Declaration of ConformityCertificate · PDF · on request

Documentation for Gas Filters Pmax: 6 Bar is issued on request against the confirmed specification. Request the document pack.

Enquire about this product

The more detail you give on the duty, the more precise the proposal comes back.

Request a quotation

Tell us the duty and we will come back with a sized proposal for Gas Filters Pmax: 6 Bar (GF-6).

Frequently asked questions

What engineers most often ask when specifying this equipment.

Match it to the most sensitive device downstream. Meters and pilot-operated regulators generally want 5 μm or finer; simple shut-off duty tolerates 25–50 μm. Going finer than required shortens element life without adding protection.